Bookmark /  Discuss  /  Edit  this page or submit new.
9 pin D-SUB male connector layout
9 pin D-SUB male connector
at the UPS
Pin #Signal TypeFunction
1Basic Modem Mode;
Input: RS232 high pulse 4 to 5 seconds wide 
Remote UPS off: In presence of  AC, Output will turn off for 15 seconds after conditionaldelay. In absence of AC, output is kept off until normal AC returns 
1Serial Data Mode;
Input: RS232 data 
RS232 serial communication input. 1200 baud, 8-bit, no parity, one stop bit, one start bit, Xon/Xoff 
2Basic Mode;
Output: RS232 level high 
AC Input failure 
2Serial Data Mode;
Output: RS232 data
RS232 serial communication output. Same as input
3Output: Open collector transistor ON, 50 mA. 40 VDC ratingAC Input failure
4Signal CommonSignal Common
5Output: Open collector transistor ON. SO mA. 40 VDC rating Impending low battery
6Input: RS232 level low (-12V)Plug and Play software enable trigger
7Input: Relay contact or RS232 level Remote output OFF/ON: UPS total output can be kept off with low signal or closing relay contact 
8Output: 8 to 25 VDC, 5 W constant power (0.63 A max. @ 8V)Auxiliary Control Power
9Chassis Connection to chassis
Is this document correct or incorrect?.
There are 1 reports in our database: 1 positive and 0 negative.
Pinouts.ru > Various peripheral devices pinouts > Pinout of Fiskars PowerRite UPS port and layout of 9 pin D-SUB male connector
This page contain parts under Copyright © 2000-2011 by pinouts.ru team.
No portion of this webpage may be reproduced in any form without providing visible HTML link to Pinouts.ru . Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.