Hardware pinouts information and cables schemes

NetApp filer head serial console cable pinout

connector or cable wiring

bookmark this page

 
Pin Number
 
Pin Name
Direction  
Pin Number
 
Pin Name
Description (may be empty)
           not used
2 Rx   3 Tx  
3 Tx   2 Rx  
            not used
5 GND   5 GND  
            not used
            not used
            not used
            not used

The absolute bare minimum: just Rx, Tx, and GND. No hardware flow control whatsoever.


This information should be correct, but may be not. Please, help us to improve this document!
Is this document CORRECT or INCORRECT? Your opinion will be used to establish document status (showed at the bottom).

Want to add or correct something here? Edit this page!
Pinouts.ru > GPS, UPS, Switches and other devices cables and adapters schematics > Pinout of NetApp filer head serial console cable
Is it correct?:
unknown
Source(s) of this and additional information: one NetApp console cable and my multimeter