Bookmark /  Discuss  /  Edit  this page or submit new.
68 pin hi-density D-SUB female connector layout
68 pin hi-density D-SUB female connector
at the controller & devices
68 pin hi-density D-SUB male connector layout
68 pin hi-density D-SUB male connector
at the cable
Pin Name Dir Description
1-16GND---Ground
17TERMPWR<->Termination Power
18TERMPWR<->Termination Power
19res<->reserved
20-34GND---Ground
35DB12<->Data Bus 12
36DB13<->Data Bus 13
37DB14<->Data Bus 14
38DB15<->Data Bus 15
39DPB1<->Data Parity (odd Parity)
40DB0<->Data Bus 0
41DB1<->Data Bus 1
42DB2<->Data Bus 2
43DB3<->Data Bus 3
44DB4<->Data Bus 4
45DB5<->Data Bus 5
46DB6<->Data Bus 6
47DB7<->Data Bus 7
48DPB<->Data Parity (odd Parity)
49GND---Ground
50GND---Ground
51TERMPWR<->Termination Power
52TERMPWR<->Termination Power
53res---reserved
54GND---Ground
55/ATN<--Attention
56GND---Ground
57/BSY<->Busy
58/ACK<--Acknowledge
59/RST<->Reset
60/MSG-->Message
61/SEL<->Select
62/C/D-->Control/Data
63/REQ-->Request
64/I/O-->Input/Output
65DB8<->Data Bus 8
66DB9<->Data Bus 9
67DB10<->Data Bus 10
68DB11<->Data Bus 11
Is this document correct or incorrect?.
There are 1 reports in our database: 0 positive and 1 negative.
Pinouts.ru > HDD connectors pinouts > Pinout of SCSI-3 Low Voltage Differential/Single Ended (LVD/SE) external connector and layout of 68 pin hi-density D-SUB female connector and 68 pin hi-density D-SUB male connector
This page contain parts under Copyright © 2000-2011 by pinouts.ru team.
No portion of this webpage may be reproduced in any form without providing visible HTML link to Pinouts.ru . Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.