This document explains the V.35 serial cable assembly and pinouts. Cisco Part#: CAB-V35MT=
60 Pin1 Signal Description Direction 34 Pin Signal
J1-49
J1-48
MODE_1
GND
Shorting group - - -
J1-50
J1-51
J1-52
MODE_0
GND
MODE_DCE
Shorting group - - -
J1-53
J1-54
J1-55
J1-56
TxC/NIL
RxC_TxCE
RxD/TxD
GND
Shorting group - - -
J1-46 Shield_GND Single - J2-A Frame GND
J1-45
Shield
Circuit_GND
-
Twisted pair no. 12 -
-
J2-B
Shield
Circuit GND
-
J1-42
Shield
RTS/CTS
-
Twisted pair no. 9 -
-
J2-C
Shield
RTS
-
J1-35
Shield
CTS/RTS
-
Twisted pair no. 8 -
-
J2-D
Shield
CTS
-
J1-34
Shield
DSR/DTR
-
Twisted pair no. 7 -
-
J2-E
Shield
DSR
-
J1-33
Shield
DCD/LL
-
Twisted pair no. 6 -
-
J2-F
Shield
RLSD
-
J1-43
Shield
DTR/DSR
-
Twisted pair no. 10 -
-
J2-H
Shield
DTR
-
J1-44
Shield
LL/DCD
-
Twisted pair no. 11 -
-
J2-K
Shield
LT
-
J1-18
J1-17
TxD/RxD+
TxD/RxD-
Twisted pair no. 1 -
-
J2-P
J2-S
SD+
SD-
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 5 -
-
J2-R
J2-T
RD+
RD-
J1-20
J1-19
TxCE/TxC+
TxCE/TxC-
Twisted pair no. 2 -
-
J2-U
J2-W
SCTE+
SCTE-
J1-26
J1-25
RxC/TxCE+
RxC/TxCE-
Twisted pair no. 4 -
-
J2-V
J2-X
SCR+
SCR-
J1-24
J1-23
TxC/RxC+
TxC/RxC-
Twisted pair no. 3 -
-
J2-Y
J2-AA
SCT+
SCT-

Arrows indicate signal direction: - indicates DTE to DCE, and - indicates DCE to DTE.

1 Any pin not referenced is not connected.

Этот документ правильный или с ошибками?.
There are 0 reports in our database: 0 positive and 0 negative.
Pinouts.ru > Кабели для последовательных портов > Распиновка Cisco V.35 DTE cable использующего разъем 60 pin Cisco DB и разъем 34 pin V.35 Cisco
This page contain parts under Copyright © 2000-2011 by pinouts.ru team.
No portion of this webpage may be reproduced in any form without providing visible HTML link to Pinouts.ru . Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.