Bookmark /  Discuss  /  Edit  this page or submit new.
60 pin Cisco DB connector layout
60 pin Cisco DB connector
15 pin Cisco DB connector layout
15 pin Cisco DB connector
This document describes the X.21 cable assembly and pinouts (Data Communications - DCE). Cisco Part#: CAB-X21FC=
60 Pin1 Signal Description Direction 15 Pin Signal
J1-48
J1-47
GND
MODE_2
Shorting group - - -
J1-46 Shield_GND Single - J2-1 Shield GND
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 6 -
-
J2-2
J2-9
Transmit+
Transmit-
J1-1
J1-2
CTS/RTS+
CTS/RTS-
Twisted pair no. 1 -
-
J2-3
J2-10
Control+
Control-
J1-11
J1-12
TxD/RxD+
TxD/RxD-
Twisted pair no. 3 -
-
J2-4
J2-11
Receive+
Receive-
J1-9
J1-10
RTS/CTS+
RTS/CTS-
Twisted pair no. 2 -
-
J2-5
J2-12
Indication+
Indication-
J1-24
J1-23
TxC/RxC+
TxC/RxC-
Twisted pair no. 4 -
-
J2-6
J2-13
Timing+
Timing-
J1-15
Shield
Control_GND
-
Twisted pair no. 5 -
-
J2-8
Shield
Control GND
-

Arrows indicate signal direction: - indicates DTE to DCE, and - indicates DCE to DTE.

1 Any pin not referenced is not connected.

Is this document correct or incorrect?.
There are 0 reports in our database: 0 positive and 0 negative.
Pinouts.ru > Serial interfaces cables and converters schemes listing > Pinout of Cisco X.21 DCE cable (DB-60 to DB-15) and layout of 60 pin Cisco DB connector and 15 pin Cisco DB connector
This page contain parts under Copyright © 2000-2011 by pinouts.ru team.
No portion of this webpage may be reproduced in any form without providing visible HTML link to Pinouts.ru . Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.