60 pin Cisco DB connector layout
Разъем 60 pin Cisco DB
used in the Cisco 7000 family, Cisco 4000 series, Cisco 3600 series, Cisco 2500 series, Cisco 1600 series, Cisco access servers, and AccessPro PC cards
60 Pin Signal Description Direction 25 Pin Signal
J1-50
J1-51
MODE_0
GND
Shorting group - - -
J1-46 Shield GND Single - J2-1 Shield GND
J1-36
Shield
RxD/TxD
-
Twisted pair no. 9 <--
-
J2-2
Shield
TxD
-
J1-41
Shield
TxD/RxD
-
Twisted pair no. 5 -->
-
J2-3
Shield
RxD
-
J1-35
Shield
CTS/RTS
-
Twisted pair no. 10 <--
-
J2-4
Shield
RTS
-
J1-42
Shield
RTS/CTS
-
Twisted pair no. 4 -->
-
J2-5
Shield
CTS
-
J1-43
Shield
DTR/DSR
-
Twisted pair no. 3 -->
-
J2-6
Shield
DSR
-
J1-45
Shield
Circuit GND
-
Twisted pair no. 1 -
-
J2-7
Shield
Circuit GND
J1-44
Shield
LL/DCD
-
Twisted pair no. 2 -->
-
J2-8
Shield
DCD
-
J1-39
Shield
TxCE/TxC
-
Twisted pair no. 7 -->
-
J2-15
Shield
TxC
-
J1-40
Shield
NIL/RxC
-
Twisted pair no. 6 -->
-
J2-17
Shield
RxC
-
J1-33
Shield
DCD/LL
-
Twisted pair no. 12 <--
-
J2-18
Shield
LTST
-
J1-34
Shield
DSR/DTR
-
Twisted pair no. 11 <--
-
J2-20
Shield
DTR
-
J1-38
Shield
RxC/TxCE
-
Twisted pair no. 8 <--
-
J2-24
Shield
TxCE
-

Arrows indicate signal direction: --> indicates DTE to DCE, and <-- indicates DCE to DTE. See also RS232 interface details.

Any pin not referenced is not connected.

Cisco Part#: CAB-232FC

25 pin Cisco DB connector layout
Разъем 25 pin Cisco DB
На эту распиновку нет ни одного отзыва! Если вы знаете, правильная она или нет, - нажмите на соответствующую кнопку ниже.

Эта распиновка
Источник(и) этой и дополнительной информации: Cisco Systems, Inc.
Copyright © 2000-2024 by pinouts.ru team, except user uploaded images.
No portion of this webpage may be reproduced in any form without visible link to pinouts.ru .
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.
Change privacy settings